New features

Issue

Description

INTL-19056

The GET_FRAME command has been added, which allows exporting still frames even when the Video Surveillance Monitor is closed.

INTL-15709

Refinements have been made to the mechanism for updating users in the Intellect core.  Previously, making changes to a user (card, facility code, or PIN code) was regarded as a deletion.

INTL-14011

Point&Click support in Intellect is now available when using 64-bit modules.

INTL-18726

CamMonitor.ocx can now be recorded for all users of a domain simultaneously.

INTL-18568

The parameter "delay<>" has been added, which allows sending an event or reaction with a delay (the length of the delay is configurable).

INTL-18900

It is now possible to change the sensitivity of the mouse scroll wheel during control of optical zoom, by adjusting the  TelemetryZoomStopTime registry key (which limits the time that the zoom command is sent to the camera and therefore the amount by which the zoom level is changed).

INTL-18884

Integration added for Everfocus EKB-200 PTZ control panels.

INTL-18445

Video Surveillance Monitor  now allows using the mouse scroll wheel to cycle through the list of archived video fragments.

Bug fixes

Issue

Description

INTL-18819

Fixed error that prevented the Client from connecting to the Server in some situations.

INTL-18895

Fixed error that prevented the Long-term Archive from resuming archiving if the main archive has been entirely archived on a previous occasion.

INTL-18938

Fixed bug that caused the itvscript.exe module to crash.

INTL-19013

In some cases the Video Surveillance Monitor did not highlight the selected archived video fragment; this has been fixed.

INTL-19024

Fixed error that prevented synchronization of times on distributed systems.

INTL-18945

Accumulation occurred in the outgoing queue on the Intellect server, causing a crash; this has been fixed.

INTL-18984

Excessive events are no longer sent by the built-in detection tools.

INTL-19060

Fixed error that prevented activating an inactive map layer.

INTL-18780

Fixed error when displaying video in the Client with use of the motionWavelet 7.1 codec.

INTL-18976

Fixed error that caused increased Server load during use of the H.264 codec.

INTL-18875

Fixed error that caused a .ddi file to fail to open during repeated attempts to edit it.

INTL-18739

Fixed error that caused incorrect display in the Event Log of the time at which the Client disconnected from the Server.

INTL-18929

Fixed error when switching to Live Video viewing via the  Enter archive button in the Operator protocol interface object

INTL-18955

In some cases the Map and Event viewer interface objects were displayed after the  Apply button was clicked; this has been fixed.

INTL-18996

During creation or deletion of some objects, commands were sent to non-existent related objects; this has been fixed.

INTL-19014

 Fixed error that caused the additional information field in the event viewer window to not be filled after restarting Intellect when the "Load protocol" check box is selected.

INTL-19069

Malfunctioning of the scrollbar when assigning screens to computers has been fixed.

INTL-18781

Fixed error that caused crashing of the video.run module on the Client in some cases when using the motionWavlet 7.1 codec.

INTL-18986

Fixed error that caused display artifacts in the operator protocol window when 64-bit video modules are running.

INTL-18730

Fixed error that caused some settings of the Converter.exe utility to take effect only after a restart of the program.

INTL-18754

The mechanism for displaying the minimum number of cameras did not function properly in Alarm cameras mode in the Video Surveillance Monitor; this has been fixed.

INTL-18958

Fixed error when controlling camera optical zoom via the Video Surveillance Monitor.

INTL-18201

Fixed error that caused artifacts in H.264 video at the moment when the write speed is changed.

INTL-18960

Fixed error that required holding down the mouse button to use Point&Click.

INTL-18966

Fixed error that caused display artifacts when playing 1080i video recorded using the motionWavelet 7.1 intr codec.

INTL-18973

The delay time of the Failover Service has been reduced in some cases.

Documentation and Localization

In Intellect 4.9.1 documentation and localization are also actualized.

List of tasks for improvement of documentation and localization: INTL-18796, INTL-18865, INTL-18847, INTL-18903